GROUND ANCHOR RANGE AND
CAPACITY
|
| |
Type |
Safe
Working Capacity Range (KN) |
| Permanent
(F0S = 3.0) |
Temporary
(FOS = 2.0) |
| |
STRAIGHTSHAFTED(Any
Soil or Rock)
diameter range 140 mm to 235 mm. |
250
to 900 |
400
to 1200 |
| |
MULTIBELL(in
clay)under ream diameter 600 mm |
400
to 650 |
500
to 900 |
| |
- Testing, stressing,
corrosion protection systems, the anchor design, and installation comply
with B.S. 8081 -1989 - Ground Anchorages.
- Straight shafted
anchors can be installed up to a maximum length of 40 m.
- The multibell
anchor overall length can be limited to 12 m to avoid encroachment beneath
third party property.
- Anchors are generally
installed in the range 20° to 40° to the horizontal or vertically
to provide uplift resistance.
- Continuous anchor
load monitoring is available using load cells incorporated into the
anchor head.
- Tendons are available
in both strand and bar.
- Our mini piling
and ground anchor techniques combine their advantages for the installation
of soil nailing systems.
|
| |
 
|